INSTRUEMENT PRODUCTS

  • Tektronix
  • Keithley
  • National Instruments
  • Delorenzo
  • Ametek
  • Digilent (An NI Company)

BROADCAST PRODUCTS

  • Telestream(Tektronix Video)
  • Harmonic
  • Streambox
  • Digital nirvana
  • Newtec
  • Utah Scientific
  • Apantac
  • DekTec
  • paneda
  • norwia
  • RFS Radio Frequency Systems
  • Tag
  • Netinsight
  • Dev
  • Irdeto

COMMUNICATION PRODUCTS

  • Netscout
  • Viavi Solutions
  • Sumitomo
  • Spirent
  • Pba
  • ROHDE&SCHWARZ
  • RFS RAdio Frequency Systems
  • SevOne
  • Efficient IP
  • A10
  • netAlly
  • ADVA
  • Tencent
  • cellex
  • GSMK
  • Microtel Innovation
  • ZCTT
  • Calnex

Vector Network Analyzer T5113A/T5230A/T5280A/T5480A

 
Overview
Transcom T5000 Series vector network analyzer offers the high RF performance, wide frequency range and versatile functions. The T5000 series is the economic solution for manufacturing and R&D engineers evaluating RF components and circuits for frequency range up to 8GHz.
Key Features
  • Frequency Range:300kHz~1.3GHz/3GHz/8GHz(T5113A/ T5230A/ T5280A)100kHz~8GHz(T5480)
  • Dynamic Range:>125 dB (IFBW=10 Hz), 130 dB typical
  • Low Noise Level:<-120 dB (IFBW=10 Hz)
  • Low Trace Noise:1 mdB rms (IFBW=3 kHz)
  • High Measurement Speed:100 μs/point (IFBW=30 kHz)
  • High Effective Directivity:>45 dB
  • Remote Control: LAN/GPIB/USB
  • Very Low Power Consumption:60W
  • One-Key-Test Solution
 
Specification
  • Measurement Range
    Product Model T5480A T5280A T5230A T5113A
    Impedance 50Ω 50Ω 50Ω75Ω1 50Ω75Ω1
    Test Port Connector N-type, female
    Number of Test Ports 4 2
    Frequency range 100kHz~8.0GHz 300kHz~8.0GHz 300kHz ~ 3.0GHz 300kHz~1.3GHz
    Full CW Frequency Accuracy ±5×10-6
    Frequency Resolution 1Hz
    Number of Measurement Points 2 ~ 10001 2 ~ 1601
    Measurement Bandwidths 1Hz to 30kHz (in 1 / 1.5 / 2 / 3 / 5 / 7 steps) 1Hz to 30kHz (in 1 / 3 steps)
     
    Dynamic Range
    115 dB, typ. 125 dB
    (100kHz~300kHz)
    135 dB, typ. 140 dB
    (300kHz~8GHz)
    125dB, typ.130dB
    Measurement Parameters S11S21, S31S41
    S12S22S32S42
    S13S23S33S43
    S14S24S34S44
    S11, S21, S12, S22 S11, S21, S12, S22 S11, S21
    1Use 75 connector via adapter
    Effective System Data
    Product Model T5480A T5280A T5230A T5113A
    Effective Directivity 46 dB 45 dB
    Effective Source Match 40 dB 40 dB
    Effective Load Match 46 dB 45 dB NA
    1 Applies over the temperature range of 23°C ± 5°C after 40 minutes of warming-up, with less than 1°C deviation from the full two-port calibration temperature, at output power of -5 dBm and IF bandwidth 10 Hz.
     
    Measurement Accuracy
    Product Model T5480A T5280A T5230A T5113A
    Accuracy of Transmission Measurements (magnitude / phase)    
    +5dB to +15dB 0.2dB/2º 0.2dB/2º (+10dB to +13dB)
    -50dB to +5dB 0.1dB/1º 0.1dB/1º (-50dB to +10dB)
    -70dB to -50dB 1.5dB/10º(100kHz~300kHz)
    0.2dB/2º(300kHz~8GHz)
    0.2dB/2º
    -90dB to -70dB 1.0dB/6º(300kHz~8GHz) 1.0dB/6º
    Accuracy of Reflection Measurements (magnitude / phase)
    -15dB to 0dB 0.4dB/3º
    -25dB to -15dB 1.0dB/6º 1.5 dB/7º
    -35dB to -25dB 3.0dB/20 4.0 dB/22º
    Trace stability
    Trace Noise Magnitude (IF bandwidth 3 kHz) 1mdBrms
    (100kHz~300kHz)
    1mdBrms
    (300kHz~8GHz)
     
    1mdB rms
     
    2 mdB rms
    Temperature Dependence (per one degree of temperature variation) 0.02 dB
     
    Measurement Speed
    Product Model T5480A T5280A T5230A T5113A
    Measurement Time Per Point 100ms 125ms 150 ms
    Source to Receiver Port Switchover Time < 10ms  
    NA
    Typical Cycle Times Versus Number of Measurement Points(IFBW 30kHz)  
     
    51 201 401 1601
    One-Path Two-Port Calibration(300kHz~1.3GHz) NA
     
    9ms 31ms 60ms 235ms
    Uncorrected(300kHz~10MHz) 13.1ms 51.3ms 102.3ms 408.3ms 13ms 52ms 104ms 413ms NA
    Full Two-Port Calibration(300kHz~10MHz) 45.5ms 122.0ms 230.5ms 840.5ms 46ms 123ms 226ms 844ms NA
    Uncorrected(10MHz~3GHz/8GHz) 6.5ms 21.1ms 40.5ms 157.7ms 7ms 27ms 53ms 207ms NA
    Full Two-Port Calibration 10MHz~3GHz/8GHz) 32.4ms 61.7ms 100.3ms 333.0ms 34ms 73ms 125ms 434ms  
    NA
     
    Test Port Output
    Product Model T5480A T5280A T5230A T5113A
    Match (W/O System Error Correction) 18 dB 15dB  
    20dB
    Power Range
    300kHz~1.3GHz/3GHz/6GHz -60dBm to +10dBm
    (100 kHz – 6 GHz)
    -60dBm to +5dBm -55dBm to +10dBm -55 dBm to +3 dBm
    6GHz~8GHz -60dBm to +5dBm NA
    Power Accuracy ±1.5 dB ±1.5 dB ±1.0dB ±1.5 dB
    Power Resolution 0.05dB
     
    Test Port Input
    Product Model T5480A T5280A T5231A T5113H
    Match (W/O System Error Correction) 18 dB 25dB  
    30dB
    Damage Level +26dBm
    Damage DC Voltage +35V
    Noise Level (IF Bandwidth 10 Hz) < -105dBm(100 kHz – 300kHz)
    < -125dBm(300 kHz – 8GHz)
    < -125dBm < -120dBm < -127dBm
     
    General Data
    Display 10.4 inch TFT color LCD, touch screen
    External Trigger Input Connector BNC female, Input level range: 0 to +5 V
    External Reference Input BNC female; 10 MHz; 2 dBm ± 3 dB (T5480A)
    BNC female; 10 MHz; 2 dBm ± 2 dB(T5280A/T5230A/T5113A)
    External Reference Output BNC female; 10 MHz; 3 dBm ± 2 dB (T5480A)
    BNC female; 10 MHz; 2 dBm ± 2 dB(T5280A/T5230A/T5113A)
    VGA Video Output 15-pin mini D-Sub; female; driving the VGA compatible monitors
    GPIB Connector (Optional) 24-pin D-Sub (type D-24), female; compatible with IEEE-488
    USB Connector Female; provides connection to printer, ECal module, USB storage
    LAN Connector 10/100/1000 Base T Ethernet, 8-pin
    Operating Temperature Range +5°C ~ +40°C
    Storage Temperature Range -45°C ~ +55°C
    Humidity 90% (25°C)
    Atmospheric Pressure 84 to 106.7 kPa
    Calibration Interval 3 yr
    Power Supply 220 ± 22 V (AC), 50 Hz
    Power Consumption 60W
    Dimensions (W × H × D) 440 ×231 ×360 mm
    Weight 13kg(T5480A)
    12.5 kg (T5280A/T5230A)
    10kg (T5113A)