Overview
T8142 is a series of signal analyzers developed by Shanghai TRANSCOM Instruments Co., Ltd. The high-performance signal analyzers are of high quality and meet the industrial standards. T8142 portable signal analyzer has small and light structure and excellent performance. With the Android intelligent operating platform and high-resolution (1080p) touch screen, the instrument is easy to carry. The excellent performance can meet the analysis requirements of the majority of RF signal applications. With the storage capacity of 1Gbit and real-time bandwidth of 20MHz, the analysis meeting mainstream communication standards is applied in the portable instrument for the first time. Signal analysis and test are made easier due to the innovative vertical screen, unique parameter icons and overall humane design. In addition, the through type power detection sensor can be applied for RF high power measurement.
T8142 is a kind of preferred instrument in installation, commissioning and maintenance of the mobile communication system, radar, national defense communication and broadcasting industry. T8142 series can fully meet the requirements of wireless applications such as the VHF, broadcasting, paging, mobile cellular system, GPS, PCS/GSM, 3G, 4G, ISM, WLAN and WLL. The easy-to-operate full touch human-machine interface can be used in high-precision and repeated tests. With the lightest and smallest structure in the industry, the instrument is easy to carry and suitable for various field applications. The powerful intelligent system platform can meet communication test needs.
Specificatio |
-
Key Functions |
Spectrum Analysis |
Quantitative interpretation for signal information in the frequency domain |
Signal Record Record |
current signal in real-time for follow-up analysis and playback |
I/Q Data Output |
Output in phase/orthogonal RF signal |
Options |
Vector Signal Analysis |
Use for various vector modulating signal analysis |
LTE Signal Analysis |
Use for LTE signal analysis |
Telecommunication Base Station Test |
Use for base station construction,maintenance |
Real Time Spectrum Analysis |
Use for capturing and analyzing transient signal |
DPX Spectrum Analysis |
Use for detecting low probability signal |
Specification |
Frequency Range |
10MHz~4.2GHz |
SPAN Range |
100Hz~full band,0Hz |
Frequency Resolution |
1Hz |
Phase Noise @1GHz |
1GHz:-96dBc/Hz,@10kHz(typical -98dBc/Hz)
-118dBc/Hz,@1MHz(typical -120dBc/Hz)
2GHz:-93dBc/Hz,@10kHz(typical -95dBc/Hz)
-116dBc/Hz,@1MHz(typical -118dBc/Hz)
4GHz:-88dBc/Hz,@10kHz(typical -90dBc/Hz)
-112dBc/Hz,@1MHz(typical -114dBc/Hz) |
Span Accuracy |
1% |
Accuracy of Reading |
(Frequency+1GHz)*1ppm(Internal Reference Aging)+Span Accuracy(1%) |
Resolution Bandwidth Accuracy |
RBW≥1MHz,±10% RBW<1MHz,±2% |
Internal Reference Aging |
±1ppm |
RBW |
10Hz~3MHz ( in 1/2/3/5/10 steps ) |
sweep time |
1ms~1600s,1us~1600s(zero span) |
sweep speed |
40GHz/Sec(RBW 1MHz) |
DNAL
|
LNA OFF(LOW)
500MHz,-133dBm/Hz(typical -135dBm/Hz)
1GHz,-131dBm/Hz(typical -133dBm/Hz)
2GHz,-130dBm/Hz(typical -132dBm/Hz)
3GHz,-124dBm/Hz(typical -126dBm/Hz)
4GHz,-126dBm/Hz(typical -128dBm/Hz)
LNA 1 级(Medium)
500MHz,-155dBm/Hz(typical -157dBm/Hz)
1GHz,-151dBm/Hz(typical -153dBm/Hz)
2GHz,-149dBm/Hz(typical -151dBm/Hz)
3GHz,-142dBm/Hz(typical -144dBm/Hz)
4GHz,-141dBm/Hz(typical -143dBm/Hz)
LNA 2 级(High)
500MHz,-168dBm/Hz(typical -170dBm/Hz)
1GHz,-168dBm/Hz(typical -170dBm/Hz)
2GHz,-165dBm/Hz(typical -167dBm/Hz)
3GHz,-157dBm/Hz(typical -159dBm/Hz)
4GHz,-156dBm/Hz(typical -158dBm/Hz) |
Maximum Measuring Power |
+20dBm |
Maximum Input Power |
+30dBm |
Input Attenuator |
0~30dB,1dB step,+1dB uncertain |
Amplitude Display |
Log/liner |
Detector Mode |
negative peak、positive peak、average、RMS、Samp |
Frequency Response Accuracy(25±5℃)
|
10 ~ 700MHz ±1dB
700 ~ 1100MHz ±2dB
1.1 ~ 3.5GHz ±1dB
3.5 ~ 3.7GHz ±2dB
3.7 ~ 4.2GHz ±1dB |
Reference Level Accuracy |
≥-60dBm,±0.8dB |
ccuracy of Scale |
±0.8dB |
Resolution uncertainty |
±0.8dB |
Amplitude Uncertain |
0.5dB |
Mixer P1dB |
-2dBm |
IIP3 |
<-60dBc(-10dBm two-tone input,LNA off) |
Second-order Harmonic Distortion |
1.6GHz 70dBc |
Mirror Response |
-50dBc |
Residual Response |
-75dBm |
ADC Parameter |
14bit,61.44MSPS |
Bandwidth |
20MHz |
SFDR |
-72dBc |
I/Q Data |
16bits,61.44/(2~16777216)MHz |
Memory Depth |
1G bits |
Display Screen |
5.5 inch,1920×1080 |
Operating Temperature |
-10~+50℃ |
Storage Temperature |
-40~+70℃ |
Operating Altitude |
lower than 4500 meters above sea level |
Battery |
11.1V 6600mAh |
Charge Information |
DC20V,charg time less than 3 hours |
Consumption |
> 9w |
Dimensions |
200×96×66(mm) |
Weight |
1.5kg |
|
|